• Constant temperature viscometer
  • DH-0506N+DHJ-8S
  • Measurement range: 1 2×1000000mPa.s, temperature control range: -5℃100℃.
  • DH-0506N+DHJ-8S
  • Constant temperature viscometer
  • Measurement range: 1 2×1000000mPa.s, temperature control range: -5℃100℃.
When the temperature deviation is 0.5℃, some liquids have a viscosity deviation of more than 5%, and temperature deviation has a great impact on viscosity. As the temperature increases, viscosity decreases. Therefore, it is especially important to keep the temperature of the measured liquid constant near the designated temperature point. For precise measurements, it is best not to exceed 0.1℃. To achieve this, our company specializes in producing constant temperature cups and constant temperature baths that are used in conjunction with DHJ series viscometers.
Product Introduction
When the temperature deviation is 0.5℃, some liquids have a viscosity deviation of more than 5%, and temperature deviation has a great impact on viscosity. As the temperature increases, viscosity decreases. Therefore, it is especially important to keep the temperature of the measured liquid constant near the designated temperature point. For precise measurements, it is best not to exceed 0.1℃. To achieve this, our company specializes in producing constant temperature cups and constant temperature baths that are used in conjunction with DHJ series viscometers.


Product Features
Constant temperature viscometer is a digital viscometer. The rotor is driven by a motor at a constant speed through a variable speed device. When the rotor rotates in the liquid, the viscosity of the liquid produces a corresponding viscous torque on the rotor. The greater the viscosity, the greater the viscous torque, and vice versa. The viscous torque acting on the rotor is detected by a sensor, and the viscosity of the liquid being measured is calculated after being processed by a computer.
Constant temperature viscometer adopts microcomputer technology, which can easily set the range (rotor number and speed), process the data detected by the sensor digitally, and display on the screen the rotor number, speed, viscosity value of the measured liquid, and the percentage of the full range, etc.
DHJ-8S is equipped with 4 rotors (No. 1, 2, 3, 4) and 8 speed levels (0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm), which can be combined into 32 different combinations to measure the viscosity of various liquids within the measuring range.
DH-0506N thermostat can control the sample temperature within the range of -5℃ to 100℃.


Technical Parameters    
Model: DHJ-8S DH-0506N
Measurement Range: 1 ~2×106mPa.s /
Rotor Specification: Rotors 1-4, optional Rotor 0 for low viscosity measurement down to 0.1mPa.s /
Rotor Speed: 0.3, 0.6, 1.5, 3, 6, 12, 30, 60 rpm /
Automatic Gear: Automatically selects the appropriate rotor and speed /
Operation Interface: Chinese/English /
Stable Reading Cursor: Vertical bar cursor displays when the reading is stable /
Measurement Accuracy: ±2% (Newtonian fluids) /
Power Supply: AC 220V±10% 50Hz±10% /
Working Environment: Temperature 5℃~35℃, relative humidity not greater than 80% /
Dimensions: 370*325*280mm 430*410*420mm
Net Weight: 6.8kg 23.5kg
Temperature Range: / -5~100(℃)
Temperature Fluctuation: / ±0.05(℃)
Temperature Control Mode: / Microcomputer temperature control, PID adjustment
Display Resolution: / 0.01(℃)
Inner Capacity: / 8L
Inner Slot Size: / 270*160*185(length*width*depth)(mm)
Opening Size(diameter): / Φ75(mm)
Pump Circulation Mode: / Internal/External circulation
Pump Flow: / 8L
Refrigeration Mode: / Compression refrigeration


Important Notes
1. The constant temperature bath should be placed on a sturdy workbench;
2. It should be free from vibration and harmful gases;
3. The ambient temperature should be relatively stable and not fluctuate too much, otherwise it will affect the temperature control accuracy. The ambient temperature should be around 25℃, especially for constant temperature baths with -40℃, -65℃, and -80℃. High ambient temperature will affect the heat dissipation of the compressor, reduce the cooling efficiency, and easily cause failures;
4. The constant temperature bath should be regularly maintained. Especially after working for a period of time, if the cooling rate slows down, the plastic mesh of the constant temperature bath should be removed and the dust on the compressor and radiator should be cleaned.
 
 


Single Page - Color Page    
Name: Author: Action:
Constant temperature viscometer   DHJ-8S+DH-0506N Viscometer Download

 

 

 

Product List
DH-0506N+DHJ-8S Unit
Host Machine Unit
Rotor 1-4 set
Rotor 0 set
Protective cover unit
Base unit
Lifting column set
Hexagonal socket head piece
A pair of pliers (one large and one small) set
Power adapter set
User manual copy
Warranty card copy
Certificate of qualification copy
Description
1
1
Optional
1
1
1
1
2
1
1
1
1